Every public CVE, as it is published
The whole CVE List, enriched with NVD scores, CISA's known exploited catalog and EPSS exploit probabilities. Updated every few minutes; last read 3 min ago.
At a glance
Published CVEs; rejected ones are not counted.
- 409,758All CVEsplus 19,189 rejected
- 928Last 24 hours4,132 in the last 7 days
- 17,668Last 30 days1,641 of them critical
- 1,786Known exploitedin the CISA KEV catalog
CVEs published per year
All time, by publication date in UTC; follows the filter above.
- Critical
- High
- Medium
- Low
- Not scored
Show the numbers as a table
| Period | Critical | High | Medium | Low | Not scored | Total | Cumulative |
|---|---|---|---|---|---|---|---|
| 2026 | 2 | 24 | 16 | 1 | 0 | 43 | 740 |
| 2025 | 2 | 33 | 25 | 1 | 0 | 61 | 697 |
| 2024 | 7 | 29 | 11 | 1 | 0 | 48 | 636 |
| 2023 | 20 | 46 | 27 | 1 | 0 | 94 | 588 |
| 2022 | 18 | 58 | 28 | 1 | 0 | 105 | 494 |
| 2021 | 15 | 42 | 24 | 6 | 0 | 87 | 389 |
| 2020 | 19 | 78 | 20 | 1 | 0 | 118 | 302 |
| 2019 | 13 | 47 | 23 | 0 | 0 | 83 | 184 |
| 2018 | 24 | 41 | 19 | 0 | 0 | 84 | 101 |
| 2017 | 3 | 8 | 6 | 0 | 0 | 17 | 17 |
| Title | ||
|---|---|---|
| CVE-2026-119055 | CWE- 416: Use After Free vulnerability exists that could cause arbitrary code execution when a local attacker could trick the end user to open a specially…Schneider Electric · EcoStruxure™ Power Build Rapsody | Medium4.6 |
| CVE-2026-102250 | CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user…Schneider Electric · Sage RTU 1410 | High8.6 |
| CVE-2026-3869 | CWE-303 : Incorrect Implementation of Authentication Algorithm vulnerability exists that could cause loss of confidentiality, integrity and availability of the…Schneider Electric · Modicon M580 | Critical9.2 |
| CVE-2026-81861 | CWE-522: Insufficiently Protected Credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU…Schneider Electric · SCADAPack 47x | Medium5.9 |
| CVE-2026-77120 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause privilege escalation…Schneider Electric · PowerLogic T300 | High8.7 |
| CVE-2026-19233 | CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized command execution and disclosure of server data when an attacker…Schneider Electric · EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) | High8.6 |
| CVE-2026-8044 | CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability exists that could cause remote code execution by an…Schneider Electric · EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) | High8.6 |
| CVE-2026-13348 | CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to a user…Schneider Electric · PowerChute™ Serial Shutdown | Medium6.9 |
| CVE-2026-13337 | CWE-564: SQL Injection: Hibernate vulnerability exists that could allow the injection of a malicious HQL query in the NetBotz database when a malicious user is…Schneider Electric · NetBotz 5 - 750/755 | Medium5.1 |
| CVE-2026-13336 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause execution of Linux…Schneider Electric · NetBotz 5 - 750/755 | High7.3 |
| CVE-2024-10085 | CWE-770: Allocation of Resources Without Limits or Throttling vulnerability exists that could cause denial of service of the OPC UA communication platform when…Schneider Electric · EcoStruxure™ OPC UA Server Expert | High8.2 |
| CVE-2026-12927 | CWE-787 Out-of-bounds write vulnerability exists that could cause loss of data or potentially risk arbitrary code execution when a malicious CGF file is…Schneider Electric · IGSS Definition (Def.exe) | High8.4 |
| CVE-2026-0667 | CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of…Schneider Electric · SCADAPack 47x | Critical9.3 |
| CVE-2026-14354 | CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially…Schneider Electric · EcoStruxure™ Cybersecurity Admin Expert | High8.7 |
| CVE-2026-9718 | CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system…Schneider Electric · PowerLogic™ P7 | Medium6.9 |
| CVE-2026-9717 | CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of…Schneider Electric · PowerLogic™ P7 | High8.6 |
| CVE-2026-9716 | CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration…Schneider Electric · PowerLogic™ P7 | High8.7 |
| CVE-2026-9651 | CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account…Schneider Electric · EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller | Medium6.7 |
| CVE-2026-9650 | CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated…Schneider Electric · EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller | High8.7 |
| CVE-2026-8045 | CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an…Schneider Electric · EcoStruxure™ IT Data Center Expert | High7.1 |
| CVE-2026-6332 | Clear Text Storage of Sensitive Information on EcoStruxure™ Machine Expert HVACSchneider Electric · Ecostruxure™ Machine Expert HVAC | Medium6.8 |
| CVE-2026-6866 | Initialization of a Resource with an Insecure Default vulnerability on EcoStruxure™ Panel ServerSchneider Electric · EcoStruxure™ Panel Server | High8.2 |
| CVE-2026-6865 | Improper Limitation of a Pathname to a Restricted Directory Vulnerability on Multiple ProductsSchneider Electric · EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller | High7.1 |
| CVE-2026-4827 | Insufficient Entropy vulnerability on Multiple ProductsSchneider Electric · Easergy MiCOM C264 | High8.7 |
| CVE-2026-2401 | CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user…Schneider Electric · PowerChute™ Serial Shutdown | Low2.4 |
| CVE-2026-2400 | CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web…Schneider Electric · PowerChute™ Serial Shutdown | Medium5.3 |
| CVE-2026-2403 | CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a…Schneider Electric · PowerChute™ Serial Shutdown | Medium5.3 |
| CVE-2026-2405 | CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web…Schneider Electric · PowerChute™ Serial Shutdown | Medium5.3 |
| CVE-2026-2402 | CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by…Schneider Electric · PowerChute™ Serial Shutdown | Medium6.9 |
| CVE-2026-2404 | CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security…Schneider Electric · PowerChute™ Serial Shutdown | Medium6.9 |
| CVE-2026-2399 | CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with…Schneider Electric · PowerChute™ Serial Shutdown | Medium6.9 |
| CVE-2026-4832 | CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated…Schneider Electric · Easergy MiCOM P14x | Medium6.9 |
| CVE-2026-2273 | CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering…Schneider Electric · EcoStruxure™ Automation Expert | High7.2 |
| CVE-2026-1286 | CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on…Schneider Electric · EcoStruxure™ Foxboro DCS | High7.0 |
| CVE-2025-13902 | CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated…Schneider Electric · Modicon Controllers M241/M251 | Medium5.1 |
| CVE-2025-13901 | CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an…Schneider Electric · Modicon M241/M251 | Medium6.9 |
| CVE-2025-11739 | CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally…Schneider Electric · EcoStruxure™ Power Monitoring Expert (PME) | High8.5 |
| CVE-2025-13957 | CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and…Schneider Electric · EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) | High7.5 |
| CVE-2026-1226 | CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when…Schneider Electric · EcoStruxure Building Operation Workstation | High7.0 |
| CVE-2026-1227 | CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within…Schneider Electric · EcoStruxure Building Operation Workstation | High7.0 |
| CVE-2025-13905 | CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service…Schneider Electric · EcoStruxure™ Process Expert | High7.0 |
| CVE-2025-13845 | CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.Schneider Electric · EcoStruxure Power Build Rapsody | High8.4 |
| CVE-2025-13844 | CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the…Schneider Electric · EcoStruxure Power Build Rapsody | High8.4 |
| CVE-2025-11567 | CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.Schneider Electric · PowerChute™ Serial Shutdown | High7.3 |
| CVE-2025-11566 | CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the…Schneider Electric · PowerChute™ Serial Shutdown | Medium6.9 |
| CVE-2025-11565 | CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web…Schneider Electric · PowerChute™ Serial Shutdown | High7.3 |
| CVE-2025-9997 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in…Schneider Electric · Saitel DR RTU | Medium5.8 |
| CVE-2025-9996 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any…Schneider Electric · Saitel DR RTU | Medium5.8 |
| CVE-2025-7746 | CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected…Schneider Electric · ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives | Medium5.3 |
| CVE-2025-8448 | CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when…Schneider Eelctric · EcoStruxure Building Operation Enterprise Server | Low1.0 |