CVE-2014-9197

Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function

Critical10.0EPSS 2.0%
Published
Updated
Reserved
Assigned by
icscert

Description

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Timeline

  1. ID reserved

    By icscert

  2. · 56 days later

    Published

  3. · 11 years later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2014-9197, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)2.0Critical10.0AV:N/AC:L/Au:N/C:C/I:C/A:C
NVDNVD · Modified2.0High7.8AV:N/AC:L/Au:N/C:C/I:N/A:N
EPSS (exploitation in 30 days)
2.0% · top 20% of all CVEs (9 Nov 2026)
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 10.0.

Weakness

Affected products

What to do

Solution: Schneider Electric has produced an updated firmware, labelled V1.60 IR 04. This firmware release moves the jar files directory in a secure area. The new firmware also includes the ability to disable the FTP server. This updated firmware can be downloaded at: http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe... http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/

Workaround: Schneider Electric recommends the FTP server be deactivated when not needed. The firmware update does not remove the hard-coded credentials. Narendra Shinde also found that configuration files were accessible using default credentials. Schneider Electric recommends users change the default login credentials. This will protect configuration files from unauthorized access.