CVE-2017-11579
In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device.…
- 7.1HighCVSS base score
- 1.6%Exploitation in 30 daysEPSS · top 25% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.
Timeline
ID reserved
By mitre
- 24 months later
· 24 months later
Published
- 5 years later
· 5 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.0 | High7.1 | CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N |
- EPSS (exploitation in 30 days)
- 1.6% · top 25% of all CVEs (10 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.1.
Affected products
n/a
- affected n/a
References
3
- 20190609 Newly releases IoT security issues (opens in a new tab)mailing-listx_refsource_BUGTRAQx_transferred
- http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html (opens in a new tab)x_refsource_MISCx_transferred
- https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf (opens in a new tab)x_refsource_MISCx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2017-3194 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2017-11579)Record last updated .