CVE-2017-20216
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 Unauthenticated Remote Command Injection
- 9.3CriticalCVSS base score
- 12.0%Exploitation in 30 daysEPSS · top 3.8% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- YesPublic exploitsa reference or SSVC says so
Description
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
Public exploit
An exploit or proof of concept is public: anyone can try it against an unpatched system. 3 references of the record are tagged as an exploit. CISA's SSVC rates its exploitation: a proof of concept is public.
Show the exploits3
References tagged exploit3 references
Timeline
ID reserved
By VulnCheck
- 1 day later
· 1 day later
Published
- 3 months later
· 3 months later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| VulnCheckCNA (assigner) | 4.0 | Critical9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| VulnCheckCNA (assigner) | 3.1 | Critical9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVDNVD · Deferred | 4.0 | Critical9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 12.0% · top 3.8% of all CVEs (9 Nov 2026)
- CISA SSVC
- Exploitation: poc · Automatable: yes · Technical impact: total
The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.3.
Affected products
FLIR Systems, Inc. · FLIR Thermal Camera PT-Series
- affected 8.0.0.64
References
5
- Zero Science Lab Vulnerability Advisory (opens in a new tab)third-party-advisoryexploit
- Exploit Database Entry 42785 (opens in a new tab)exploit
- Packet Storm Security Exploit Archive (opens in a new tab)exploit
- CXSecurity Vulnerability Listing (opens in a new tab)third-party-advisory
- Archived FLIR Security Advisory (opens in a new tab)vendor-advisorypatch
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)