Skip to content
CVE Ledger
  • Newest CVEsPage
  • Recently added to KEVPage
  • Rising exploitation (EPSS)Page
  • Weekly digestPage
  • StatisticsPage
  • WatchlistPage
  • API docsPage
  • MCP serverPage
  • AboutPage
  • Data sourcesPage
  • Data statusPage
  • ChangelogPage
  • How it's builtPage
  • Support the projectPage

14 results

Back

CVE-2018-10626

Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity

Description

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.

Timeline

  1. ID reserved

    By icscert

  2. · 3 months later

    Published

  3. · 8 years later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2018-10626, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)3.1Medium4.4CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N
NVDNVD · Modified3.1Medium4.4CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N
EPSS (exploitation in 30 days)
0.36% · top 70% of all CVEs (11 Nov 2026)
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 4.4.

Affected products

What to do

Workaround: Medtronic has made server-side updates to address this insufficient verification vulnerability. Medtronic is implementing additional server-side mitigations to enhance data integrity and authenticity.

Workaround: Medtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should: * Maintain good physical control over the home monitor. * Only use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system.

Workaround: Medtronic has released additional patient focused information, at the following location: https://www.medtronic.com/security

Workaround: Users should follow CISA's guidance in the following areas: * Securing the Internet of Things https://www.cisa.gov/news-events/news/securing-internet-things-iot * Home Network Security https://www.cisa.gov/news-events/news/home-network-security

References

References5

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2018-10626 badge
[![CVE-2018-10626](https://cveledger.app/badge/CVE-2018-10626.svg)](https://cveledger.app/cve/CVE-2018-10626)

Record last updated .