CVE-2018-19616
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators…
- 8.1HighCVSS base score
- 30.3%Exploitation in 30 daysEPSS · top 1.8% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- 1Public exploitsMetasploit, Nuclei and Exploit-DB
Description
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
Public exploit
An exploit or proof of concept is public: anyone can try it against an unpatched system. The public collections list an Exploit-DB entry for it. A reference of the record is tagged as an exploit.
Show the exploits2
Exploit-DB1 entry
- Rockwell Automation Allen-Bradley PowerMonitor 1000 - Incorrect Access Control Authentication Bypass (Exploit-DB entry) (opens in a new tab)
EDB-ID 45937webapps, hardwarepublished 4 Dec 2018Not verified
References tagged exploit1 reference
- 45937 (opens in a new tab)exploitx_refsource_EXPLOIT-DBx_transferred
Modules, templates and exploits as listed by the Metasploit Framework (BSD-3-Clause), ProjectDiscovery's Nuclei templates (MIT) and the Exploit Database (GPLv2), read once a day. Where the data comes from
Timeline
ID reserved
By mitre
- 29 days later
· 29 days later
Published
- 6 years later
· 6 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.0 | High8.1 | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
- EPSS (exploitation in 30 days)
- 30.3% · top 1.8% of all CVEs (10 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.1.
Affected products
n/a
- affected n/a
References
5
- https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04 (opens in a new tab)x_refsource_MISCx_transferred
- http://packetstormsecurity.com/files/150619/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-Authentication-Bypass.html (opens in a new tab)x_refsource_MISCx_transferred
- 106333 (opens in a new tab)vdb-entryx_refsource_BIDx_transferred
- 45937 (opens in a new tab)exploitx_refsource_EXPLOIT-DBx_transferred
- 108538 (opens in a new tab)vdb-entryx_refsource_BIDx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2018-11303 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2018-19616)Record last updated .