CVE-2018-4833
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch…
- 8.8HighCVSS base score
- 0.95%Exploitation in 30 daysEPSS · top 38% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
Timeline
ID reserved
By siemens
- 5 months later
· 5 months later
Published
- 6 years later
· 6 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.0 | High8.8 | CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
- EPSS (exploitation in 30 days)
- 0.95% · top 38% of all CVEs (9 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.8.
Affected products
- affected All versions
- affected V4.4, V4.5, V5.0, and V5.1
Siemens · SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- affected All versions < V5.2.3
Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
- affected All versions < V5.4.1
Siemens · SCALANCE X-200RNA switch family
- affected All versions < V3.2.6
Siemens · SCALANCE X-300 switch family (incl. SIPLUS NET variants)
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions
- affected All versions
References
1
- https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf (opens in a new tab)x_refsource_MISCx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2018-16619 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)