A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
Timeline
ID reserved
By siemens
- 3 months later
· 3 months later
Published
- 7 years later
· 7 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.1 | Medium6.7 | CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N |
- EPSS (exploitation in 30 days)
- 0.42% · top 63% of all CVEs (9 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 6.7.
Affected products
Siemens AG · SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS
- affected SIMATIC WinCC OA UI for Android : All versions < V3.15.10
- affected SIMATIC WinCC OA UI for iOS : All versions < V3.15.10
References
2
- https://cert-portal.siemens.com/productcert/pdf/ssa-822928.pdf (opens in a new tab)x_refsource_CONFIRMx_transferred
- 103475 (opens in a new tab)vdb-entryx_refsource_BIDx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2018-16630 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2018-4844)Record last updated .