CVE-2019-10942A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT…
- 8.6HighCVSS base score
- 1.4%Exploitation in 30 daysEPSS · top 28% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
Timeline
ID reserved
By siemens
- 4 months later
· 4 months later
Published
- 5 years later
· 5 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.1 | High8.6 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H |
- EPSS (exploitation in 30 days)
- 1.4% · top 28% of all CVEs (15 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.6.
Affected products
Siemens · SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- affected All versions < V5.2.5
Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
- affected All versions < V5.5.0
Siemens · SCALANCE X204RNA (HSR)
- affected All versions
Siemens · SCALANCE X204RNA (PRP)
- affected All versions
Siemens · SCALANCE X204RNA EEC (HSR)
- affected All versions
Siemens · SCALANCE X204RNA EEC (PRP)
- affected All versions
Siemens · SCALANCE X204RNA EEC (PRP/HSR)
- affected All versions
References
References1
- https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf (opens in a new tab)x_refsource_MISCx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2019-2656 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2019-10942)Record last updated .