CVE-2019-13924A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All…
- 5.4MediumCVSS base score
- 0.83%Exploitation in 30 daysEPSS · top 42% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Timeline
ID reserved
By siemens
- 7 months later
· 7 months later
Published
- 4 years later
· 4 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.1 | Medium5.4 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N |
- EPSS (exploitation in 30 days)
- 0.83% · top 42% of all CVEs (15 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.4.
Affected products
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- affected All versions < 5.2.4
Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
- affected All versions < V5.5.0
Siemens · SCALANCE X-200RNA switch family
- affected All versions < V3.2.7
Siemens · SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)
- affected All versions < 4.1.3
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2019-5194 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2019-13924)Record last updated .