CVE-2020-11639Insufficient access control on Inter process communication,

Description

An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.

Timeline

  1. ID reserved

    By ABB

  2. · 4 years later

    Published

  3. · 12 days later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2020-11639, by who scored it
Scored byCVSSScoreVector
ABBCNA (assigner)3.1High7.8CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
NVDNVD · Analyzed3.1High7.8CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS (exploitation in 30 days)
0.13% · top 98% of all CVEs (17 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.8.

Affected products

What to do

Solution: ABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service accounts. Please note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where AdvaBuild is used. All the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the “Mitigating factors” listed below as this will restrict or prevent an attacker’s ability to compromise the system.