CVE-2021-20593Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A…
- 7.1HighCVSS base score
- 0.85%Exploitation in 30 daysEPSS · top 41% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior) and Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) allows a remote authenticated attacker to impersonate administrators to disclose configuration information of the air conditioning system and tamper information (e.g. operation information and configuration of air conditioning system) by exploiting this vulnerability.
Timeline
ID reserved
By Mitsubishi
- 7 months later
· 7 months later
Published
- 3 years later
· 3 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.1 | High7.1 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N |
- EPSS (exploitation in 30 days)
- 0.85% · top 41% of all CVEs (17 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.1.
Affected products
Air Conditioning System/Centralized Controllers G-50A; GB-50A; AG-150A-A; AG-150A-J; GB-50ADA-A; GB-50ADA-J; EB-50GU-A; EB-50GU-J; AE-200A; AE-200E; AE-50A; AE-50E; EW-50A; EW-50E; TE-200A; TE-50A; TW-50A; CMS-RMD-J; Air Conditioning System/Expansion Controllers PAC-YG50ECA
- affected Ver.2.50 to Ver.3.35
- affected Ver.3.20 and prior
- affected Ver 7.09 and prior
- affected Ver 7.93 and prior
- affected Ver.1.30 and prior
- affected Ver.2.20 and prior
References
References2
- https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-004_en.pdf (opens in a new tab)x_refsource_MISCx_transferred
- https://jvn.jp/vu/JVNVU96046575/index.html (opens in a new tab)x_refsource_MISCx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2021-8011 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2021-20593)Record last updated .