CVE-2021-33023Advantech WebAccess

Description

Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code.

Timeline

  1. ID reserved

    By icscert

  2. · 5 months later

    Published

  3. · 3 years later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2021-33023, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)3.1Critical9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVDNVD · Modified3.1Critical9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS (exploitation in 30 days)
2.3% · top 16% of all CVEs (17 Nov 2026)
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.8.

Affected products

What to do

Solution: In order to address the heap-based buffer overflow vulnerability, Advantech recommends users directly add the remote access code to avoid being attacked by unknown requests. This is the remote access code established during installation of the Advantech WebAccess SCADA software (SCADA node, project node, or OPC Service) on the OPC Server computer. The access code you enter here must match the remote access code established during installation on the OPC Server. This prevents unauthorized users from accessing the OPC Server data using the Advantech WebAccess SCADA OPC Service. If you have forgotten the remote access code using during software installation on the OPC Server node, you have two options: Re-install the Advantech WebAccess SCADA software on the OPC Server node to change it and edit it to match in your database. Edit the BWSERVER.INI file on the OPC Server node and edit it to match in your database using UPDATE.

References

References1

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2021-33023 badge
[![CVE-2021-33023](https://cveledger.app/badge/CVE-2021-33023.svg)](https://cveledger.app/cve/CVE-2021-33023)

Record last updated .