CVE-2021-38405Siemens Solid Edge, JT2Go, and Teamcenter Visualization Improper Restriction of Operations within the Bounds of a Memory Buffer
- 7.8HighCVSS base score
- 1.3%Exploitation in 30 daysEPSS · top 30% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Timeline
ID reserved
By icscert
- 2 years later
· 2 years later
Published
- 9 months later
· 9 months later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| icscertCNA (assigner) | 3.1 | High7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
| NVDNVD · Modified | 3.1 | High7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
- EPSS (exploitation in 30 days)
- 1.3% · top 30% of all CVEs (16 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.8.
Affected products
- affected < 13.2.0.7
Siemens · Teamcenter Visualization
- affected 12.4 – < 12.4.0.13
- affected 13.1 – < 13.1.0.8
- affected 13.2 – < 13.2.0.7
- affected 13.3 – < 13.3.0.1
What to do
Solution: Siemens has released updates for some of the affected products and recommends updating to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not yet available. * JT2Go: Update to v13.2.0.7 https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html or later version * Teamcenter Visualization v13.1: Update to v13.1.0.9 or later version https://support.sw.siemens.com/ * Teamcenter Visualization v13.2: Update to v13.2.0.7 or later version https://support.sw.siemens.com/ * Teamcenter Visualization v13.3: Update to v13.3.0.1 or later version https://support.sw.siemens.com/ Please see Siemens security advisory SSA-301589 https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf for more information.
Workaround: Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk: * Avoid opening untrusted files from unknown sources in affected products. As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf , and to follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage https://www.siemens.com/industrialsecurity . Please see Siemens security advisory SSA-301589 https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf for more information.
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2021-24857 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2021-38405)Record last updated .