CVE-2022-2069Datalogics APDFL library Heap-based Buffer Overflow

Description

The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.

Timeline

  1. ID reserved

    By icscert

  2. · 4 months later

    Published

  3. · 2 years later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2022-2069, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)3.1High7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
NVDNVD · Modified3.1High7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS (exploitation in 30 days)
0.46% · top 59% of all CVEs (12 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.8.

Affected products

What to do

Solution: Siemens recommends updating to the latest version: Teamcenter Visualization V13.3: Update to version 13.3.0.5 or later Teamcenter Visualization V14.0: Currently no fix available. JT2Go V13.3.0.5: Update to version 13.3.0.5 or later For more information see Siemens Security Advisory SSA-829738

Workaround: Avoid opening untrusted files in JT2Go and Teamcenter Visualization As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ and to follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found on Siemens’ Industrial Security webpage. For more information see Siemens Security Advisory SSA-829738