CVE-2022-25753A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE…
- 8.8HighCVSS base score
- 1.7%Exploitation in 30 daysEPSS · top 22% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.
Timeline
ID reserved
By siemens
- 49 days later
· 49 days later
Published
- 2 years later
· 2 years later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.1 | High8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
- EPSS (exploitation in 30 days)
- 1.7% · top 22% of all CVEs (15 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.8.
Affected products
Siemens · SCALANCE X302-7 EEC (230V)
- affected All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (230V, coated)
- affected All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (24V)
- affected All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (24V, coated)
- affected All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 230V)
- affected All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 230V, coated)
- affected All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 24V)
- affected All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 24V, coated)
- affected All versions < V4.1.4
- affected All versions < V4.1.4
Siemens · SCALANCE X306-1LD FE
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (230V)
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (230V, coated)
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (24V)
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (24V, coated)
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (2x 230V)
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (2x 230V, coated)
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (2x 24V)
- affected All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (2x 24V, coated)
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
Siemens · SCALANCE X308-2M PoE
- affected All versions < V4.1.4
Siemens · SCALANCE X308-2M PoE
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
- affected All versions < V4.1.4
Siemens · SCALANCE X320-1-2LD FE
- affected All versions < V4.1.4
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (230V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (230V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (230V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (230V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (24V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (24V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (24V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M (24V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M TS (24V)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-12M TS (24V)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (24V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (24V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (24V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (24V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (230V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (230V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (24V, ports on front)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (24V, ports on rear)
- affected All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE TS (24V, ports on front)
- affected All versions < V4.1.4
Siemens · SIPLUS NET SCALANCE X308-2
- affected All versions < V4.1.4
References
References1
- https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf (opens in a new tab)x_refsource_MISCx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2022-30408 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket