CVE-2022-31483Arbitrary file write via authenticated OSDP file upload

Description

An authenticated attacker can upload a file with a filename including “..” and “/” to achieve the ability to upload the desired file anywhere on the filesystem. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.271. This allows a malicious actor to overwrite sensitive system files and install a startup service to gain remote access to the underlaying Linux operating system with root privileges.

Timeline

  1. ID reserved

    By Carrier

  2. · 14 days later

    Published

  3. · 2 years later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2022-31483, by who scored it
Scored byCVSSScoreVector
CarrierCNA (assigner)3.1Critical9.1CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
NVDNVD · Modified3.1High8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS (exploitation in 30 days)
1.8% · top 21% of all CVEs (13 Nov 2026)
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.1.

Affected products

What to do

Solution: Update to the latest version of firmware

Workaround: Disable the controller's Web Server. When the controller is configured to disable web access, you cannot remotely login into the controller’s web page. 1. Login to controller web pages 2. Go to “Users” Tab 3. Near bottom of the Users page, check option to “Disable Web Server” 4. Then select “Submit” at the bottom of the page 5. Then select “Apply Settings” tab 6. And on that page, select button “Apply Settings, Reboot” The Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller.