14 results

Back

CVE-2022-41648The HEIDENHAIN Controller TNC 640 NC software Version 340590 07 SP5, is vulnerable to improper authentication in its DNC communication for…

Description

The HEIDENHAIN Controller TNC 640 NC software Version 340590 07 SP5, is vulnerable to improper authentication in its DNC communication for CNC machines. Authentication is not enabled by default for DNC communication. This vulnerability may allow an attacker to deny service on the production line, steal sensitive data from the production line, and alter any products created by the production line. Note: CNC machines running the TNC 640 controller require DNC to be enabled for DNC communication to be present.

Timeline

  1. ID reserved

    By icscert

  2. · 29 days later

    Published

  3. · 3 years later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2022-41648, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)4.0Critical9.2CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
NVDNVD · Modified4.0Critical9.2CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.88% · top 40% of all CVEs (15 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.2.

Affected products

What to do

Solution: HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk: * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system. * Use zone firewalls to isolate and segment the network of the affected devices. * Ask your machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.

Workaround: HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk: * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system. * Use zone firewalls to isolate and segment the network of the affected devices. * Ask machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.

References

References2

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2022-41648 badge
[![CVE-2022-41648](https://cveledger.app/badge/CVE-2022-41648.svg)](https://cveledger.app/cve/CVE-2022-41648)

Record last updated .