Skip to content
CVE Ledger
  • Newest CVEsPage
  • Recently added to KEVPage
  • Rising exploitation (EPSS)Page
  • Weekly digestPage
  • StatisticsPage
  • WatchlistPage
  • API docsPage
  • MCP serverPage
  • AboutPage
  • Data sourcesPage
  • Data statusPage
  • ChangelogPage
  • How it's builtPage
  • Support the projectPage

14 results

Back

CVE-2023-1258Flow-X disclosure of sensitive information to unauthenticated users

Description

Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0.

Public exploit

An exploit or proof of concept is public: anyone can try it against an unpatched system. The public collections list an Exploit-DB entry for it.

Show the exploits1

Exploit-DB1 entry

Modules, templates and exploits as listed by the Metasploit Framework (BSD-3-Clause), ProjectDiscovery's Nuclei templates (MIT) and the Exploit Database (GPLv2), read once a day. Where the data comes from

Timeline

  1. ID reserved

    By ABB

  2. · 24 days later

    Published

  3. · 23 months later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2023-1258, by who scored it
Scored byCVSSScoreVector
ABBCNA (assigner)3.1Medium5.3CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
NVDNVD · Modified3.1Medium5.3CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
EPSS (exploitation in 30 days)
3.9% · top 9.6% of all CVEs (15 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: yes · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.3.

Affected products

What to do

Workaround: To minimize the risk of unauthorized access to sensitive information, ABB recommends to only operate Flow-X flow computers in secure networks. Additionally, ABB recommends that HTTPS is used to communicate with the Flow-X web server. HTTPS support has been implemented since version 1.2.2 (available as of June 2016) and is enabled by default since version 3.2.0 (available as of September 2020). To minimize the risk of exposed security information on one device leading to unauthorized access on other devices, ABB recommends that customers change the usernames and passwords that are part of the standard application and to use different usernames and password on different devices

References

References2

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2023-1258 badge
[![CVE-2023-1258](https://cveledger.app/badge/CVE-2023-1258.svg)](https://cveledger.app/cve/CVE-2023-1258)

Record last updated .