CVE-2023-26293A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation…
- 7.3HighCVSS base score
- 0.25%Exploitation in 30 daysEPSS · top 84% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
Timeline
ID reserved
By siemens
- 49 days later
· 49 days later
Published
- 20 months later
· 20 months later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| siemensCNA (assigner) | 3.1 | High7.3 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C |
| NVDNVD · Modified | 3.1 | High7.3 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L |
- EPSS (exploitation in 30 days)
- 0.25% · top 84% of all CVEs (13 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: total
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.3.
Affected products
Siemens · Totally Integrated Automation Portal (TIA Portal) V15
- affected < *
Siemens · Totally Integrated Automation Portal (TIA Portal) V16
- affected < V16 Update 7
Siemens · Totally Integrated Automation Portal (TIA Portal) V17
- affected < V17 Update 6
Siemens · Totally Integrated Automation Portal (TIA Portal) V18
- affected < V18 Update 1
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2023-30116 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2023-26293)Record last updated .