CVE-2023-6094OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials
- 5.3MediumCVSS base score
- 0.24%Exploitation in 30 daysEPSS · top 85% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.
Timeline
ID reserved
By Moxa
- 48 days later
· 48 days later
Published
- 8 months later
· 8 months later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| MoxaCNA (assigner) | 3.1 | Medium5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| NVDNVD · Modified | 3.1 | Medium5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
- EPSS (exploitation in 30 days)
- 0.24% · top 85% of all CVEs (15 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: partial
The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.3.
Affected products
Moxa · OnCell G3150A-LTE Series
- affected 1.0 – ≤ 1.3
What to do
Workaround: Since Oncell G3150A-LTE has been phased out, we don’t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. Moxa recommends users to implement the following mitigations if necessary: * Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. * Place control system networks and remote devices behind firewalls, isolating them from business networks. * When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2023-58350 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2023-6094)Record last updated .