CVE-2024-32753TYCO Illustra Pro Gen 4 - JQuery version
- 7.0HighCVSS base score
- 0.40%Exploitation in 30 daysEPSS · top 65% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
Under certain circumstances the camera may be susceptible to known vulnerabilities associated with the JQuery versions prior to 3.5.0 third-party component
Timeline
ID reserved
By jci
- 3 months later
· 3 months later
Published
- 36 days later
· 36 days later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| jciCNA (assigner) | 4.0 | High7.0 | CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N |
| NVDNVD · Deferred | 4.0 | High7.0 | CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 0.40% · top 65% of all CVEs (15 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: yes · Technical impact: partial
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.0.
Affected products
Johnson Controls · TYCO Illustra Pro4 Fixed cameras
- affected ≤ Illustra.SS016.05.03.01.0007
Johnson Controls · TYCO Illustra Pro4 PTZ cameras
- affected ≤ Illustra.SS010.24.03.00.0005
Johnson Controls · TYCO Illustra Flex4 Fixed & PTZ cameras
- affected ≤ Illustra.SS018.24.03.00.0010
Johnson Controls · TYCO Illustra Pro4 MultiSensor Cameras
- affected ≤ Illustra.SS017.24.03.00.0009
Johnson Controls · TYCO Illustra Flex4 DualSensor Cameras
- affected ≤ Illustra.SS022.24.03.00.0008
What to do
Solution: * Update firmware of Pro4 Fixed cameras to Illustra.SS016.24.03.00.0007 * Update firmware of Pro4 PTZ cameras to Illustra.SS010.24.03.00.0005 * Update firmware of Flex4 Fixed & PTZ cameras to Illustra.SS018.24.03.00.0010 * Update firmware of Pro4 MultiSensor cameras to Illustra.SS017.24.03.00.0009 * Update firmware of Flex4 DualSensor cameras to Illustra.SS022.24.03.00.0008
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)