CVE-2024-4622alpitronic Hypercharger EV Charger Use of Default Credentials
- 8.3HighCVSS base score
- 0.49%Exploitation in 30 daysEPSS · top 57% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface protected by authentication. If the default credentials are not changed, an attacker can use public knowledge to access the device as an administrator.
Timeline
ID reserved
By icscert
- 8 days later
· 8 days later
Published
- 11 months later
· 11 months later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| icscertCNA (assigner) | 4.0 | High8.3 | CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N |
| NVDNVD · Deferred | 4.0 | High8.3 | CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 0.49% · top 57% of all CVEs (13 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: partial
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.3.
Affected products
alpitronic · Hypercharger EV Charger
- affected all versions
What to do
Workaround: alpitronic recommends users change the default credentials for all charging devices. alpitronic advises that the interface should be connected only to internal segregated and access-controlled networks and not exposed to the public internet/web. When informed of these vulnerabilities, alpitronic, in conjunction with and/or on behalf of affected clients, disabled the interface on any exposed devices and all clients were contacted directly and reminded that the interface is not intended to be visible on the public Internet and that default passwords should be changed. alpitronic are also applying mitigations to all devices in the field and to new devices in production. New devices will come with unique passwords. Devices using the default password will be automatically assigned new unique passwords, or at first access if the device has not yet been installed. Devices with the default passwords already changed will not be affected. New passwords can be obtained by scanning the QR-Code inside the charger or in DMS portal hyperdoc. Contact Hypercharger support with any questions about newly assigned passwords.
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2024-44230 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2024-4622)Record last updated .