- 7.1HighCVSS base score
- 0.99%Exploitation in 30 daysEPSS · top 37% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- YesPublic exploitsa reference or SSVC says so
Description
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Public exploit
An exploit or proof of concept is public: anyone can try it against an unpatched system. A reference of the record is tagged as an exploit. CISA's SSVC rates its exploitation: a proof of concept is public.
Show the exploits1
References tagged exploit1 reference
Timeline
ID reserved
By VulDB
Published
- 34 days later
· 34 days later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| VulDBCNA (assigner) | 4.0 | High7.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N |
| VulDBCNA (assigner) | 3.1 | Medium6.5 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H |
| VulDBCNA (assigner) | 3.0 | Medium6.5 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H |
| VulDBCNA (assigner) | 2.0 | Medium6.8 | AV:N/AC:L/Au:S/C:N/I:N/A:C |
| NVDNVD · Modified | 4.0 | High7.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 0.99% · top 37% of all CVEs (11 Nov 2026)
- CISA SSVC
- Exploitation: poc · Automatable: no · Technical impact: partial
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.1.
Affected products
References
References4
- VDB-269947 | Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow (opens in a new tab)vdb-entrytechnical-descriptionx_transferred
- VDB-269947 | CTI Indicators (IOB, IOC, IOA) (opens in a new tab)signaturepermissions-requiredx_transferred
- Submit #360696 | Tenda A301V2.0 Firmware V15.13.08.12 buffer overflow (opens in a new tab)third-party-advisoryx_transferred
- https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md (opens in a new tab)exploitx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2024-47507 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2024-6402)Record last updated .