CVE-2024-8580TOTOLINK AC1200 T8 shadow.sample hard-coded password
- 9.2CriticalCVSS base score
- 1.3%Exploitation in 30 daysEPSS · top 28% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- YesPublic exploitsa reference or SSVC says so
Description
A vulnerability classified as critical was found in TOTOLINK AC1200 T8 4.1.5cu.861_B20230220. This vulnerability affects unknown code of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Public exploit
An exploit or proof of concept is public: anyone can try it against an unpatched system. A reference of the record is tagged as an exploit. CISA's SSVC rates its exploitation: a proof of concept is public.
Show the exploits1
References tagged exploit1 reference
Timeline
ID reserved
By VulDB
- 1 day later
· 1 day later
Published
- 1 day later
· 1 day later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| VulDBCNA (assigner) | 4.0 | Critical9.2 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| VulDBCNA (assigner) | 3.1 | High8.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
| VulDBCNA (assigner) | 3.0 | High8.1 | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
| VulDBCNA (assigner) | 2.0 | High7.6 | AV:N/AC:H/Au:N/C:C/I:C/A:C |
| NVDNVD · Analyzed | 4.0 | Critical9.2 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 1.3% · top 28% of all CVEs (12 Nov 2026)
- CISA SSVC
- Exploitation: poc · Automatable: no · Technical impact: total
The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.2.
Affected products
References
References5
- VDB-276814 | TOTOLINK AC1200 T8 shadow.sample hard-coded password (opens in a new tab)vdb-entry
- VDB-276814 | CTI Indicators (IOB, IOC, TTP, IOA) (opens in a new tab)signaturepermissions-required
- Submit #401293 | TOTOLINK AC1200 T8 V4.1.5cu.861_B20230220 Use of Hard-coded Password (opens in a new tab)third-party-advisory
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/AC1200T8/shadow.md (opens in a new tab)exploit
- https://www.totolink.net/ (opens in a new tab)product
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2024-49283 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2024-8580)Record last updated .