CVE-2025-11784Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
- 8.5HighCVSS base score
- 0.40%Exploitation in 30 daysEPSS · top 65% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Timeline
ID reserved
By INCIBE
- 48 days later
· 48 days later
Published
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| INCIBECNA (assigner) | 4.0 | High8.5 | CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H |
| NVDNVD · Analyzed | 4.0 | High8.5 | CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 0.40% · top 65% of all CVEs (15 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: total
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.5.
Affected products
SGE-PLC1000 SGE-PLC50 · Circutor
- affected 9.0.2
What to do
Solution: The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API.
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2025-200232 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2025-11784)Record last updated .