CVE-2025-1242Administrative Credentials Can Be Extracted Through Gardyn API Responses
- 9.3CriticalCVSS base score
- 0.57%Exploitation in 30 daysEPSS · top 52% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicious control.
Timeline
ID reserved
By icscert
- 13 months later
· 13 months later
Published
- 56 days later
· 56 days later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| icscertCNA (assigner) | 4.0 | Critical9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N |
| icscertCNA (assigner) | 3.1 | Critical9.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N |
| NVDNVD · Deferred | 4.0 | Critical9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 0.57% · top 52% of all CVEs (17 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: yes · Technical impact: total
The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.3.
Affected products
- affected < master.619
Gardyn · Home Kit Mobile Application
- affected < 2.11.0
- affected < 2.12.2026
What to do
Solution: For all vulnerabilities, Gardyn recommends users ensure their home kit devices are upgraded to firmware master.619 or later. Gardyn also recommends that users update their mobile application to the most recent version. Gardyn requests that users ensure their home kits have network connectivity in order to automatically download needed firmware updates. Unconnected devices will automatically update when configured with a working Internet connection.
Solution: Further information on Gardyn security can be found here: https://mygardyn.com/security/
Solution: Further customer support can be obtained from Gardyn at: [email protected]
References
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)