CVE-2025-59105Unencrypted Flash Storage in dormakaba access manager

Description

With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.

Timeline

  1. ID reserved

    By SEC-VLab

  2. · 5 months later

    Published

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2025-59105, by who scored it
Scored byCVSSScoreVector
SEC-VLabCNA (assigner)4.0High7.0CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
NVDNVD · Deferred4.0High7.0CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.11% · top 99% of all CVEs (18 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.0.

Affected products

What to do

Solution: A firmware update to at least BAME 06.00.x RA is recommended. Hardware access and special equipment are required to exploit this vulnerability. In general, the Access Manager should be installed in a secured area and protected by a tamper contact.