CVE-2025-62498AutomationDirect Productivity Suite Relative Path Traversal

Description

A relative path traversal (ZipSlip) vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an attacker who can tamper with a productivity project to execute arbitrary code on the machine where the project is opened.

Timeline

  1. ID reserved

    By icscert

  2. · 2 days later

    Published

  3. · 1 day later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2025-62498, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)4.0High8.6CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
icscertCNA (assigner)3.1High8.8CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
NVDNVD · Deferred4.0High8.6CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.54% · top 54% of all CVEs (19 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.6.

Affected products

What to do

Solution: AutomationDirect recommends that users do the following: * Update the Productivity Suite programming software to version 4.5.0.x or higher. * Update the firmware of Productivity PLCs to the latest version. https://www.automationdirect.com/support/software-downloads * Although automation networks and systems come equipped with built-in password protection mechanisms, this represents a fraction of the security measures needed to safeguard these systems. * It is imperative that automation control system networks integrate data protection and security measures that match, if not exceed, the robustness of conventional business computer systems. * AutomationDirect advises users of PLCs, HMI products, and SCADA systems to conduct a thorough network security analysis to ascertain the appropriate level of security necessary for their specific application.

Workaround: AutomationDirect has identified the following mitigations for instances where systems cannot be upgraded to the latest version: * Physically disconnect the PLC from any external networks, including the internet, local area networks (LANs), and other interconnected systems. * Configure network segmentation to isolate the PLC from other devices and systems within the organization. * Implement firewall rules or network access control (NAC) policies to block incoming and outgoing traffic to the PLC. * Please refer to AutomationDirect's security considerations https://support.automationdirect.com/docs/securityconsiderations.pdf  for additional information. * If you have any questions regarding this issue, please contact AutomationDirect Technical Support at 770-844-4200 or 800-633-0405 for further assistance.