14 results

Back

CVE-2026-11889SALTO ProAccess Space Authorization Bypass Through User-Controlled Key

Description

SALTO ProAccess Space software using the tenancy feature / logical partition is vulnerable to a privilege escalation attack that could allow an authorized attacker to access any space managed by the affected product.

Timeline

  1. ID reserved

    By icscert

  2. · 36 days later

    Published

  3. · 1 day later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2026-11889, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)4.0High7.1CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N
icscertCNA (assigner)3.1Medium6.5CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
NVDNVD · Awaiting Analysis4.0High7.1CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.31% · top 76% of all CVEs (16 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.1.

Affected products

What to do

Solution: Users of SALTO ProAccess using the tenancy feature should upgrade to version 6.13. To further enhance security after applying the update:  * Operate ProAccess Space on a protected internal network and avoid exposing it directly to the Internet.  * Restrict operator-level accounts to the minimum required and apply least-privilege principles.  * If feasible, disable the partitioning feature and operate under a single partition.  * When strong tenant separation is required, consider running separate Space instances (isolated environments) rather than relying solely on logical partitioning.

References

References2

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2026-11889 badge
[![CVE-2026-11889](https://cveledger.app/badge/CVE-2026-11889.svg)](https://cveledger.app/cve/CVE-2026-11889)

Record last updated .