CVE-2026-133851FlowIntel Alerting: Missing Private Case Authorization Check Allows Connector Owners to Access Revoked Case Data
- 5.3MediumCVSS base score
- 0.32%Exploitation in 30 daysEPSS · top 83% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0.
Timeline
ID reserved
By CIRCL
Published
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| CIRCLCNA (assigner) | 4.0 | Medium5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N |
| NVDNVD · Deferred | 4.0 | Medium5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 0.32% · top 83% of all CVEs (26 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: partial
The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.3.
Affected products
What to do
Solution: The fix enforces private case visibility as a mandatory gate before any connector-ownership check can grant alert access. If an alert is linked to a private case and the user cannot view that case, access is denied regardless of ownership. A post-commit re-verification is added after review-status updates and after detecting a competing case-creation claim, ensuring that concurrent association changes do not result in unauthorized data disclosure in the response.
References
References1
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2026-131590 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2026-133851)Record last updated .