Skip to content
CVE Ledger
  • Newest CVEsPage
  • Recently added to KEVPage
  • Rising exploitation (EPSS)Page
  • Weekly digestPage
  • StatisticsPage
  • WatchlistPage
  • API docsPage
  • MCP serverPage
  • AboutPage
  • Data sourcesPage
  • Data statusPage
  • ChangelogPage
  • How it's builtPage
  • Support the projectPage

14 results

Back

CVE-2026-133851FlowIntel Alerting: Missing Private Case Authorization Check Allows Connector Owners to Access Revoked Case Data

Description

FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0.

Timeline

  1. ID reserved

    By CIRCL

  2. Published

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2026-133851, by who scored it
Scored byCVSSScoreVector
CIRCLCNA (assigner)4.0Medium5.3CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
NVDNVD · Deferred4.0Medium5.3CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.32% · top 83% of all CVEs (26 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.3.

Affected products

What to do

Solution: The fix enforces private case visibility as a mandatory gate before any connector-ownership check can grant alert access. If an alert is linked to a private case and the user cannot view that case, access is denied regardless of ownership. A post-commit re-verification is added after review-status updates and after detecting a competing case-creation claim, ensuring that concurrent association changes do not result in unauthorized data disclosure in the response.

References

References1

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2026-133851 badge
[![CVE-2026-133851](https://cveledger.app/badge/CVE-2026-133851.svg)](https://cveledger.app/cve/CVE-2026-133851)

Record last updated .