Back

CVE-2026-16687Power System Buffer Overflow

Description

IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact.

Timeline

  1. ID reserved

    By ibm

  2. · 27 days later

    Published

  3. · 3 days later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2026-16687, by who scored it
Scored byCVSSScoreVector
ibmCNA (assigner)3.1Critical9.6CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
NVDNVD · Analyzed3.1Critical9.6CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
EPSS (exploitation in 30 days)
0.35% · top 71% of all CVEs (19 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.6.

Affected products

  • IBM · Power Systems Firmware

    • affected FW1120.00
    • affected FW1110.00 – ≤ FW1110.30
    • affected FW1060.00 – ≤ FW1060.80
    • affected FW950.00 – ≤ FW950.H2

What to do

Solution: IBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible. Power 11 1) IBM Power System E1180 (9080-HEU) IBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible. Power 10 1) IBM Power System E1080 (9080-HEX) IBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible. Power 9 1) IBM Power System S922 (9009-22G) 2) IBM Power System H922 (9223-22S) 3) IBM Power System S914 (9009-41G) 4) IBM Power System S924 (9009-42G) 5) IBM Power System H924 (9223-42S) 6) IBM Power System E950 (9040-MR9) 7) IBM Power System E980 (9080-M9S) The images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/

Workaround: Protect access to the FSP's network interface.

References

References1

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2026-16687 badge
[![CVE-2026-16687](https://cveledger.app/badge/CVE-2026-16687.svg)](https://cveledger.app/cve/CVE-2026-16687)