CVE-2026-16832Power System Buffer Overflow
- 8.4HighCVSS base score
- 0.32%Exploitation in 30 daysEPSS · top 75% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.
Timeline
ID reserved
By ibm
- 26 days later
· 26 days later
Published
- 3 days later
· 3 days later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| ibmCNA (assigner) | 3.1 | High8.4 | CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
| NVDNVD · Analyzed | 3.1 | High8.4 | CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
- EPSS (exploitation in 30 days)
- 0.32% · top 75% of all CVEs (16 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: total
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.4.
Affected products
- affected FW1120.00
- affected FW1110.00 – ≤ FW1110.30
- affected FW1060.00 – ≤ FW1060.80
- affected FW950.00 – ≤ FW950.H2
What to do
Solution: Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability. Power 11 1) IBM Power System E1180 (9080-HEU) Customers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability. Power 10 1) IBM Power System E1080 (9080-HEX) Customers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability. Power9 1) IBM Power System S922 (9009-22G) 2) IBM Power System H922 (9223-22S) 3) IBM Power System S914 (9009-41G) 4) IBM Power System S924 (9009-42G) 5) IBM Power System H924 (9223-42S) 6) IBM Power System E950 (9040-MR9) 7) IBM Power System E980 (9080-M9S) The images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/
Workaround: Protect access to the FSP's network interface.
References
References1
- https://www.ibm.com/support/pages/node/7283895 (opens in a new tab)vendor-advisorypatch
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2026-62690 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2026-16832)Record last updated .