Skip to content
CVE Ledger
  • Newest CVEsPage
  • Recently added to KEVPage
  • Rising exploitation (EPSS)Page
  • Weekly digestPage
  • StatisticsPage
  • WatchlistPage
  • API docsPage
  • MCP serverPage
  • AboutPage
  • Data sourcesPage
  • Data statusPage
  • ChangelogPage
  • How it's builtPage
  • Support the projectPage

14 results

Back

CVE-2026-19492This Power System update is being released to address

Description

IBM PowerVM Hypervisor FW1120.00 through FW1120.01, FW1110.00 through FW1110.31, and FW1060.00 through FW1060.81 is affected by a vulnerability in a hypervisor call interface. An attacker with root access to a guest partition can read a limited amount of hypervisor memory, potentially exposing sensitive data belonging to the hypervisor or other guest partitions hosted on the same system, resulting in a confidentiality impact. The attacker has no control over which memory contents are returned. This vulnerability is of particular concern in multi-tenant environments where guests may run arbitrary OS images.

Timeline

  1. ID reserved

    By ibm

  2. · 45 days later

    Published

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2026-19492, by who scored it
Scored byCVSSScoreVector
ibmCNA (assigner)3.1Low3.2CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:N
NVDNVD · Analyzed3.1Low3.2CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:N
EPSS (exploitation in 30 days)
0.11% · top 98% of all CVEs (18 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Low 3.2.

Affected products

  • IBM · PowerVM Hypervisor

    • affected FW1120.00 – ≤ FW1120.01
    • affected FW1110.00 – ≤ FW1110.31
    • affected FW1060.00 – ≤ FW1060.81

What to do

Solution: Customers with the products below should install FW1110.32(1110_138), FW1120.02(1120_171), or newer to remediate this vulnerability. Power 11 * IBM Power System E1180 (9080-HEU) Customers with the products below should install FW1110.32(1110_160), FW1120.02(1120_195), or newer to remediate this vulnerability. Power 11 * IBM Power System S1122 (9824-22A) * IBM Power System S1124 (9824-42A) * IBM Power System S1122s (9824-22B) * IBM Power System S1114 (9824-41B) * IBM Power System L1122 (9856-22H) * IBM Power System L1124 (9856-42H) * IBM Power System E1150 (9043-MRU) Customers with the products below should install FW1120.02(1120_195), or newer to remediate this vulnerability. Power 11 * IBM Power System S1112 (9242-21B, 9242-21T) Customers with the products below should install FW1060.82(1060_189), or newer to remediate this vulnerability. Power 10 * IBM Power System E1080 (9080-HEX) Customers with the products below should install  FW1060.82(1060_199), or newer to remediate this vulnerability. Power 10 * IBM Power System S1022 (9105-22A) * IBM Power System S1024 (9105-42A) * IBM Power System S1022s (9105-22B) * IBM Power System S1014 (9105-41B) * IBM Power System L1022 (9786-22H) * IBM Power System L1024 (9786-42H) * IBM Power System E1050 (9043-MRX) * IBM Power System S1012 (9028-21B) The images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/

References

References1

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2026-19492 badge
[![CVE-2026-19492](https://cveledger.app/badge/CVE-2026-19492.svg)](https://cveledger.app/cve/CVE-2026-19492)

Record last updated .