- 9.2CriticalCVSS base score
- 0.45%Exploitation in 30 daysEPSS · top 60% of all CVEs
- NoKnown exploitednot in CISA's KEV catalog
- NonePublic exploitsnone known yet
Description
A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."
Timeline
ID reserved
By VulDB
Published
- 2 days later
· 2 days later
Record updated
Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| VulDBCNA (assigner) | 4.0 | Critical9.2 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P |
| VulDBCNA (assigner) | 3.1 | High8.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| VulDBCNA (assigner) | 3.0 | High8.1 | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| VulDBCNA (assigner) | 2.0 | High7.6 | AV:N/AC:H/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR |
| NVDNVD · Deferred | 4.0 | High8.2 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
- EPSS (exploitation in 30 days)
- 0.45% · top 60% of all CVEs (11 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: total
The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.2.
Affected products
Besen · BS20 EV Charging Station
- affected 20260426
References
4
- VDB-365378 | Besen BS20 EV Charging Station OTA Update Installation improper authorization (opens in a new tab)vdb-entry
- VDB-365378 | CTI Indicators (IOB, IOC, TTP) (opens in a new tab)signaturepermissions-required
- Submit #813576 | Besen EV Charging Station BS20 EV Charger Embedded Malicious Code (opens in a new tab)third-party-advisory
- https://github.com/carfeii/besen#finding-4-unauthorized-firmware-installation-via-spoofed-ota-updates (opens in a new tab)patch
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- EUVD EUVD-2026-31551 (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://cveledger.app/cve/CVE-2026-9397)Record last updated .